Level 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
Famco Fireplace Services in Lansdale: What to Know First
We provide independent Famco fireplace services in Lansdale, from gas insert tune-ups to firebox rebuilds, with a written price before any work starts and a documented photo record when we’re done. Most Famco jobs book within a week, and we carry common parts for the VGM and VGI series on our trucks. If you own a Famco gas fireplace, wood-burning unit, or insert in Lansdale and want the repair done under a 365-Day Done Right Promise, call us at (267) 327-4785. Corrine Halstead and our crew have worked on Famco products across Montgomery County since 2009, including the older VGM-36 units common in the colonials near the Merrick Road corridor.
What happens when you call
- 1
A real person answersNo phone trees - you reach a local pro.
- 2
You get an upfront price rangeHonest numbers before anyone is dispatched.
- 3
A background-checked tech heads outLicensed & insured, dispatched right away.
- 4
You approve before work beginsNothing starts until you say go.
How Famco Products Fail - and How We Fix Them
- VGM series pilot assembly failures. The standing pilot on VGM-36 and VGM-42 units tends to soot up when Lansdale’s hard water minerals calcify in the gas orifice. We pull the assembly, ultrasonic-clean the pilot body, and replace the thermopile if millivolt output drops below 325 mV. If the orifice is scaled past recovery, we source an OEM pilot from our Haven buying network rather than forcing a generic fit.
- VGI insert blower motor bearing noise. The GFK-160A blower in VGI inserts runs at 3,000 RPM and the sleeve bearings dry out after roughly six seasons of Lansdale’s dry winter cycling. We don’t lubricate and hope; we replace with a sealed-ball-bearing aftermarket equivalent that matches OEM CFM and amp draw, documented in your photo record.
- Firebox refractory panel cracking in VFB models. Famco’s refractory panels are 1.5-inch castable, but rapid thermal cycling from overfiring splits them at the bolt holes. We measure the crack width and depth with a camera and feeler gauge. Under 1/8 inch and stable, we seal with HeatShield refractory sealant. Through-cracked or displaced, we order factory-matched panels through our Olympia Chimney supply line.
- VGK vent-free ODS (oxygen depletion sensor) nuisance shutdowns. The ODS on VGK-24 and VGK-30 units is sensitive to lint and dust accumulation, but in Lansdale’s older homes with forced-air heat, we also see shutdowns from negative pressure when bath fans or range hoods run simultaneously. We clean the ODS pilot, check room air volume against ANSI Z21.11.2 requirements, and tell you honestly if the unit is oversized for the space.
- VGW wood-burning fireplace smoke chamber deterioration. The smoke chamber above the firebox in VGW-42 units is parged with a thin refractory slurry that flakes with repeated freeze-thaw if the chimney cap leaks. We camera-scan the chamber, measure parging loss with a depth gauge, and re-parge with Chamber-Tech 2000 or recommend a stainless liner if the corbeling is too extreme to meet the 1:12 slope rule in NFPA 211.
Our Famco Fireplace Services Process

- 1
Call and schedule. A live person answers, checks our Famco parts stock for your model, and books a two-hour window. You get a text when your tech is en route.
- 2
Camera-scan inspection. We run a chimney camera per NFPA 211 Level 2 standards, regardless of whether the job is gas or wood. For Famco inserts, we also scope the vent connector and termination. The camera doesn’t guess. Neither do we.
- 3
Written price and scope. Before any tool touches your fireplace, you receive a written price, written scope, and written warranty. Clause 1 of the Haven Standard: have it in writing. No exceptions.
- 4
Parts decision. If your Famco part is available OEM through our Famco supply channel, we quote it. If lead time exceeds ten days and a quality aftermarket equivalent meets or exceeds OEM spec, we show you both options with the price difference.
- 5
Repair and test. We complete the work, run combustion analysis on gas units (CO, O2, draft pressure), or do a smoke-puff test on wood units. Readings go in your documented photo record.
- 6
Cleanup and documentation. We leave the work area as we found it. You get your photo record, written warranty, and a 365-Day Done Right Promise stamped on the invoice. Haven Standard Clause 4 requires the archive; we’ve done it since 2009.
Before
AfterWhat Famco Fireplace Services Costs in Lansdale
| Service | Typical Range | What Moves the Price |
|---|---|---|
| VGM/VGK pilot assembly cleaning or replacement | $185 - $340 | OEM vs. aftermarket pilot; thermopile included or separate |
| VGI blower motor replacement | $280 - $450 | Motor brand; whether housing gasket is reusable |
| VFB refractory panel repair (sealant) | $220 - $380 | Panel count; access through face or from above |
| VFB refractory panel replacement | $680 - $1,200 | OEM panel availability; shipping from Famco warehouse |
| VGW smoke chamber re-parging | $890 - $1,650 | Chamber height; scaffolding needs; liner condition |
| Full VGK ODS diagnostic and repair | $165 - $295 | ODS replacement vs. room-air correction only |
Every estimate is free. We don’t start work until you’ve seen the camera footage, read the written price, and signed the scope. Call (267) 327-4785 to book.
Why Lansdale Homeowners Call Level Two Chimney Lansdale for Famco Work

We’re independently owned and operated, not a franchise, and we’ve completed more than 38,000 chimney inspections and cleanings since 2009. Every Famco job gets the same documentation standard: camera down the flue or vent, written price before work starts, and a photo record when we’re done. Our technicians are background-checked and uniformed; your license number is on the page, and you know who’s coming before they knock.
We also carry DuraFlex liners, HeatShield refractory products, and Gelco caps on our trucks, so if your Famco repair reveals a deeper issue, we don’t disappear for two weeks waiting on parts. The 365-Day Done Right Promise applies to everything we touch. And if another company handed you a written estimate that doesn’t sit right, our Free Second Opinion is exactly that: free, written, and honest about what you actually need.
FAQs
No. As an independent Famco service provider, we use OEM or equivalent parts and document our work to manufacturer standards. Famco warranties cover defects in materials and workmanship; they don’t require you to use a factory-authorized technician for routine service or repair. We note part numbers and installation dates in your record so any future warranty claim has the paper trail it needs.
Most common VGM and VGI parts arrive in three to five business days through our Haven buying network. Older VFB refractory panels or discontinued VGK components can stretch to two weeks. We always quote both OEM and quality aftermarket options if the aftermarket part meets spec and ships faster, with the price difference shown in writing before you decide.
We recommend replacement when repair costs exceed 60% of a comparable new insert installed, or when the firebox is cracked through and no longer structurally sound. For a 15-year-old VGM-36 with a failed gas valve and deteriorating refractory, we’ll show you the camera footage and run both numbers. If the repair buys you five reliable years at half the replacement cost, we’ll say so plainly. Nothing is recommended without evidence you can see.
NFPA 211 recommends annual inspection for all solid-fuel appliances. In Lansdale, where we burn October through April and many homeowners run their VGW units as primary heat, we find Class II creosote buildup by mid-season in about 40% of the chimneys we scan. A Level 2 inspection with camera documentation each fall catches it before it becomes a chimney fire risk. Call (267) 327-4785 to schedule before burning season starts.
Deferred maintenance on a VGM or VGI unit typically leads to pilot failure, blower seizure, or incomplete combustion producing elevated carbon monoxide. The ODS on VGK models is a safety device, not a maintenance substitute; a dirty ODS can shut down your heat on the coldest night of the year. We don’t use scare tactics, but we do show you the soot accumulation, the bearing wear, or the CO reading on our analyzer. Then you decide. Call (267) 327-4785 for a free estimate.
Written by Corrine Halstead, Owner, Level Two Chimney Lansdale at Level Two Chimney Lansdale, serving Lansdale and nearby areas.





Before
After
Before
After
Before
After